Ocular and oral swabs were collected twice daily for 30 days. DNA was extracted from all swabs and HSV-1 DNA copy numbers were determined. Statistical analysis was performed to compare the DNA copy numbers of the three groups.\n\nRESULTS. There was no significant difference in the HSV-1 DNA copy numbers in the tears or saliva among any of the three treatment groups. The
mean copy numbers +/- SE of mean (SEM) of HSV-1 DNA in tears were 340 +/- 35, SN-38 1074 +/- 320, and 630 +/- 51 for groups 1, 2, and 3, and in saliva were 238 +/- 35, 963 +/- 462, and 493 +/- 25, respectively, for groups 1, 2, and 3.\n\nCONCLUSIONS. No correlation was found between HSV-1 shedding and valacyclovir and valacyclovir with aspirin treatment. The HSV-1 DNA copy number was not reduced
by treatment with 500 mg of valacyclovir daily or with a combination of daily valacyclovir (500 mg) plus twice-daily doses of aspirin (350 mg) over 30 days. (Invest Ophthalmol Vis Sci. 2009; 50: 5601-5608) DOI: 10.1167/iovs.09-3729″
“Purpose: To develop a software-based scatter correction method for digital breast tomosynthesis (DBT) imaging and investigate its impact on the image quality of tomosynthesis reconstructions of both phantoms and patients.\n\nMethods: A Monte Carlo (MC) simulation of x-ray scatter, with geometry matching that of the cranio-caudal (CC) view of a DBT clinical prototype, was developed using the Geant4 toolkit and used to generate BLZ945 in vivo maps of the scatter-to-primary ratio (SPR) of a number of homogeneous standard-shaped breasts of varying sizes. Dimension-matched
SPR maps were then deformed and registered to DBT acquisition projections, allowing for the estimation of the primary x-ray signal acquired by the imaging system. Noise filtering of the estimated projections was then performed to reduce the impact of the quantum noise of the x-ray scatter. Three dimensional check details (3D) reconstruction was then performed using the maximum likelihood-expectation maximization (MLEM) method. This process was tested on acquisitions of a heterogeneous 50/50 adipose/glandular tomosynthesis phantom with embedded masses, fibers, and microcalcifications and on acquisitions of patients. The image quality of the reconstructions of the scatter-corrected and uncorrected projections was analyzed by studying the signal-difference-to-noise ratio (SDNR), the integral of the signal in each mass lesion (integrated mass signal, IMS), and the modulation transfer function (MTF).\n\nResults: The reconstructions of the scatter-corrected projections demonstrated superior image quality. The SDNR of masses embedded in a 5 cm thick tomosynthesis phantom improved 60%-66%, while the SDNR of the smallest mass in an 8 cm thick phantom improved by 59% (p < 0.01).