02, p=0.4511). In addition, in a multiple logistic regression model, adjusted for all the other variables, PAI-1 was observed to be independently associated with CAD > 70% (p<0.001).\n\nConclusion: The most important finding of this study was the association between 4G/4G genotype, high plasma PAI-1 levels and coronary stenosis higher than 70% in Brazilian individuals. Whether high plasma PAI-1 levels are a decisive factor for atherosclerosis worsening or it is a consequence remains
to be established. (Arq Bras Cardiol 2011;97(6):462-467)”
“Objective Volumetric impedance indices derived from spatiotemporal image correlation (STIC) power Doppler ultrasound (PDU) might overcome the influence of machine settings and attenuation. We examined the feasibility of obtaining these indices from spherical
this website samples of anterior placentas in healthy pregnancies, and assessed intraobserver reliability and correlation with conventional umbilical artery (UA) impedance indices. Methods Uncomplicated singleton pregnancies with anterior placenta were HKI-272 nmr included in the study. A single observer evaluated UA pulsatility index (PI), resistance index (RI) and systolic/diastolic ratio (S/D) and acquired three STIC-PDU datasets from the placenta just above the placental cord insertion. Another observer analyzed the STIC-PDU datasets using Virtual Organ Computer-aided AnaLysis (VOCAL) spherical samples from every frame
to determine the vascularization index (VI) and vascularization flow index (VFI); maximum, minimum and average values were used to determine the three volumetric impedance indices (vPI, vRI, vS/D). Intraobserver reliability was examined by intraclass correlation coefficients (ICC) and association between volumetric indices from placenta, and UA Doppler indices were assessed by Pearson’s correlation coefficient. Results A total of 25 pregnant women were evaluated but five were excluded because of artifacts observed ASP2215 chemical structure during analysis. The reliability of measurement of volumetric indices of both VI and VFI from three STIC-PDU datasets was similar, with all ICCs = 0.78. Pearson’s r values showed a weak and non-significant correlation between UA pulsed-wave Doppler indices and their respective volumetric indices from spherical samples of placenta (all r ? 0.23). VOCAL indices from specific phases of the cardiac cycle showed good repeatability (ICC = 0.92). Conclusion Volumetric impedance indices determined from spherical samples of placenta are sufficiently reliable but do not correlate with UA Doppler indices in healthy pregnancies. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.”
“The aim of this study was to characterize the subgroups of solitary fibrous tumor (SET) and to investigate the expression of different biomarkers including CD34 and IGF2 in malignant transformation.